• Login
    View Item 
    •   AUW IR
    • Faculty Research
    • Science & Math
    • Current Faculties
    • Moinul Haque Meaze
    • Articles
    • 2013
    • View Item
    •   AUW IR
    • Faculty Research
    • Science & Math
    • Current Faculties
    • Moinul Haque Meaze
    • Articles
    • 2013
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Angular distribution in the neutron-induced fission of actinides

    Thumbnail
    View/Open
    2013 (5).pdf (396.5Kb)
    Date
    2013
    Author
    Meaze, AKM Moinul Haque
    Metadata
    Show full item record
    Abstract
    Above 1 MeV of incident neutron energy the fission fragment angular distribution (FFAD) has generally a strong anisotropic behavior due to the combination of the incident orbital momentum and the intrinsic spin of the fissioning nucleus. This effect has to be taken into account for the efficiency estimation of devices used for fission cross section measurements. In addition it bears information on the spin deposition mechanism and on the structure of transitional states. We designed and constructed a detection device, based on Parallel Plate Avalanche Counters (PPAC), for measuring the fission fragment angular distributions of several isotopes, in particular 232Th. The measurement has been performed at n_TOF at CERN taking advantage of the very broad energy spectrum of the neutron beam. Fission events were recognized by back to back detection in coincidence in two position-sensitive detectors surrounding the targets. The detection efficiency, depending mostly on the stopping of fission fragments in backings and electrodes, has been computed with a Geant4 simulation and validated by the comparison to the measured case of 235U below 3 keV where the emission is isotropic. In the case of 232Th, the result is in good agreement with previous data below 10 MeV, with a good reproduction of the structures associated to vibrational states and the opening of second chance fission. In the 14 MeV region our data are much more accurate than previous ones which are broadly scattered.
    URI
    repository.auw.edu.bd:8080//handle/123456789/935
    Collections
    • 2013 [7]

    DSpace software copyright © 2002-2022  LYRASIS
    Contact Us | Send Feedback
    Theme by 
    Atmire NV
     

     

    Browse

    All of AUW Institutional RepositoryCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    DSpace software copyright © 2002-2022  LYRASIS
    Contact Us | Send Feedback
    Theme by 
    Atmire NV